Model 565SD User Guide
4. Reassemble plug element into microphone and seal setscrew
securely by turning out (clockwise).
SET SCREW
PLUG
ELEMENT
PIN 3
IMPEDANCE
SELECTION SOCKET
GENERALIMPEDANCE SELECTION-
The UNISPHERE I 565 Series microphones are dual-imped-RECEPTACLE END OF MICROPHONE
FIGURE 1
ance, unidirectional dynamic microphones with a strong,
wire-mesh, spherical front grille that contains a highly effective POLARITY
wind and ?pop? filter.
All cables and microphones should be tested to ensure that they
Shipped connected for low-impedance operation, 565 Series
have the same polarity. To test two microphones and/or their ca-
microphones provide excellent vocal or speech reproduction on
bles for proper polarity, connect them to an amplifier and talk or
lecterns and stages, and are a popular choice for use in public au-
sing into them while holding them three or four inches apart. The
ditoriums, churches, convention halls, and schools.
sound from the speakers should be the same when talking into ei-
FEATURESther microphone or directly between them. If the sound drops dras-
tically, or if a dead spot is found when talking between the two
?Selectable dual impedance operation
microphones, either the microphones or their cables have opposite
?Silent magnetic reed on/off switch with lock-on option
polarity.
?Cardioid dynamic
To change the polarity of a microphone cable, either use a
?Frequency response: 50 to 15,000 Hz
Shure A15PRS phase reverser or interchange the wires connected
MODEL VARIATIONSto pins 2 and 3 of the three-pin connector at one end of the cable.
To change the polarity of a microphone, the microphone cartridge
Model 565SD-CN: Supplied with 6.1 m (20 ft) XLR cable.leads must be interchanged. This should be performed by your
Model 565SD-LC: No cable supplied.dealer, the Shure Factory Service Department, or other qualified
service personnel.
CONNECTIONS
When using the microphone with a balanced input, pins 2 and 3 SPECIFICATIONS
are the audio signal carriers. When using the microphone with an
Type
unbalanced input, use a cable wired with pin 2 as the signal carrier
Dynamic
and pin 3 connected to the cable shield (ground), such as the Frequency Response
Shure C20HZ high-impedance cable.
50 to 15,000 Hz
IMPEDANCE SELECTION+20
The microphone is shipped connected for low impedance oper-
ation. To change to high impedance, proceed as follows (refer to +10
Figure 1):
1. Remove plug element at receptacle end of microphone by 0dB
turning slotted setscrew in (counterclockwise) and carefully
withdrawing plug element from case.-10
2. Disconnect 2-terminal impedance selection socket from rear
of plug element.-20
3. Reconnect 2-terminal impedance selection socket in reverse 293 4 5 67892 3 4 5 678
2050 100100010000 20000
position so that pin 3 of plug element is inserted in socket ter-
minal ?H? (White).Hz
?2005, Shure IncorporatedPrinted in U.S.A.
27C3060 (Rev. 7) |